Welcome to the TRNSYS Users Forum.

The forum is a place where people can interact and have discussions about different topics involving the use of the TRNSYS software package. Here you can post topics for discussion or questions on using TRNSYS and get advice from other users or TRNSYS experts. This forum is not intended for detailed technical support. Users should contact their distributor’s hotline for such assistance.

Some tips for success on using the forum:

  • Follow the Forum Rules posted in Forum Administration.
  • There are categories for different types of topics and questions. Post your topic or question into the proper category.
  • Before posting a topic or question search the existing topics  (and the TRNSYS Users listserv archive or Post archive) to see if a similar topic or question has already been answered.
  • Use a descriptive topic name. Don’t use attention getting subjects, they don’t get attention and only annoy people.
  • State the version of TRNSYS and which add-ons your are using.
  • Include enough specific details for your topic of question to be answered. Just posting “Why am I getting an error?” without describing the specific error and what you are trying to do when you get the error will not receive a response that fixes your issue.
  • Remember when people help you, they are doing you a favor. Be patient, help people out by posting good descriptions of what you need help with, and be polite even if a response does not solve your issue.
  • Moderators may edit your post for clarity or move your topic to a more appropriate category.

DavidBradley
@davidbradley
Admin
Member
Joined: Jan 20, 2023
Last seen: Feb 14, 2025
Topics: 30 / Replies: 196
Reply
Answer to: Active Layer and Stack Overflow

Yuri, It might be a good idea to send your project and any files needed in order to run it to your distributor. They've got tools they can use to ...

2 years ago
Reply
Answer to: Error 105: Types not found

There are a few possibilities. You mention that you copied in the proformas. The TESS Libraries are provided as an installer that should put all of th...

2 years ago
Topic
Reply
Answer to: Wizard Settings created by SketchUp-TRNSYS plugin

1) if I do not want to use blinds, can I set SHADE_CLOSE = 100000 and SHADE_OPEN = 0? both should be set to 10000 (100000 is fine too). SHADE_CLOSE ...

2 years ago
Reply
Answer to: Evaporation tank with resistances

Pablo, Interesting problem! I think there are two ways that you can go about this. One is to write a tank model that has an outputs for (at leas...

2 years ago
Reply
Answer to: Boundary Wall

When your building's geometry has been created in SketchUp/Trnsys3d there are a number of aspects of the building that you cannot change from the drop...

2 years ago
Reply
RE: Model calibration and finding optimum capacitance of furnished airnodes

@tm-abir-ahsan There is a model of a lumped capacitance in the TESS Loads and Structures library (Type963). It can be coupled to Type56 to model a v...

2 years ago
Reply
RE: Invalid floating point operation

@ayoub-nassa. There are no issues of compatibility between 18.04 and 18.05. You should be able to open the file in the new version and run it with no ...

2 years ago
Reply
RE: Fortran - TypeStudio Editing an Obsolete Type - Type 60l ( horizontal tank with internal HEX) - conversion .for to .f90

@mehdi_s Mehdi, I realize this is not exactly an answer to your question but may I ask why you are working with Type60? There are horizontally ...

2 years ago
Reply
Answer to: How can I add PCM wall from Type 56

I am aware of three possibilities for modeling PCMs in a Type56 building. Transsolar and TESS both offer add-on components for sale. Transsolar's is...

2 years ago
Reply
RE: Vertical ground heat exchanger

@JJLiu Hi Jingjing, You can set the number of preheat years to zero in which case the other values don't matter. In case it is useful in fut...

2 years ago