Christian,
Make sure that the new dll they gave you is in both the
..\Trnsys17\UserLib\ReleaseDLLs\ and in the
..\Trnsys17\UserLib\DebugDLLs\ directories. If you still get error
105 then check the *.f90 code (you can open it with a text
editor). There should be a line near the top that says:
!DEC$ATTRIBUTES DLLEXPORT :: TYPE3399
the name on that line is the important one for loading the DLL.
The name of the file is not relevant. If the number in the
DLLEXPORT line is wrong then the author should be able to make a
quick fix and give you another compiled version of it.
kind regards,
David
On 05/24/2016 09:52, Christian Herløv
Krintel via TRNSYS-users wrote:
David,
Thank you for your reply. I have been in contact with the author
of Type399, as you suggested, who sent a recompiled .dll file with
a new type number.
However, when running the simulation, TRNSYS cannot find the new
type in the dll libraries (error message 105).
I also tried to rename the dll file to "Type3399.dll", which is
the new type name.
I suspect that the source code was not adapted properly to the new
type number. I have the .f90 source code. Is there any way for me
to compile it myself? I tried using the following guide with the
free g95 compiler, but I get errors. Maybe this guide is only for
fixed format .for files?
http://sel.me.wisc.edu/trnsys/downloads/tutorials_and_examples/tutex17.htm
Any help would be greatly appreciated :)
Best Regards
Christian Krintel
Technical University of Denmark
David BRADLEY skrev den 2016-05-20 18:16:
Christain and Maroun,
I would be very careful about workarounds. If you run a
simulation
that has one instance of a component in it, then drag out a
second
instance and the results of the first change then it is almost
certain
that the Type was not programmed in such a way as to allow there
to be
multiple instances in a simulation. They are sharing some data
structures internally and there isn't really any way of getting
around
that except if you use a compiler to make a copy of the Type,
give it
a new Type number, then recompile and link it into its own DLL.
In general the better solution is to be in contact with the
author of
Type399 (or with the distributor from whom you purchased it) and
see
if they can assist.
kind regards,
David
On 05/20/2016 11:02, NEMAR Maroun via TRNSYS-users wrote:
Christian,
I met almost the same problem two months ago, and I have
solved
hardly. I don't know how can I show you through email, if you
could
mail me your project and your PCM components to compare it
with mine
then to fix it for you. If there any problem with you PCM
component,
I'll make you know, if not I'll fix the problem the same way
I've
done.
Best regards,
MAROUN NEMAR
Building performance engineer
BUILDING ENERGY ANALYSIS & ENGINEERING
T: 0620548116
E: maroun.nemar@gmail.com
web site : www.bureauveritas.fr [1]
2016-05-20 16:38 GMT+01:00 Christian Herløv Krintel
<trnsys-users@lists.onebuilding.org>:
Dear TRNSYS users,
I have a multizone building model, where I want to use two
PCM
components (Type 399) to model the ceilings of two adjacent
rooms.
When I run the simulation I noticed that the two components
somehow share information. The PCM temperature is the same
in both
components.
I tried to switch the component order in the Control Cards,
which
changes the PCM temperature, but they are still equal.
How can I run two instances of a type side-by-side? Is this
a
limitation in how Type 399 was programmed?
Best Regards
Christian
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org
--
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
22 North Carroll Street - suite 370
Madison, WI 53703 USA
P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com
http://www.tess-inc.com
http://www.trnsys.com
Links:
------
[1] http://www.bureauveritas.fr/
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org
--
***************************
David BRADLEY