[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Window importation failure



Susana,

  The steps that you describe are the correct ones and I just made a very simple example to make sure that there is not a fundamental problem with importing adjacent windows. 


  There is a maximum number of surfaces allowed in a model so it is possible that may be the problem. I have also had models that just turned sour on me and I have found in some cases that I just had to delete the windows (or walls) that were not importing correctly and then redraw them.

 

  If none of those ideas solves the problem then you should send the *.idf and *.b18 into your distributor to see if they can offer some help.

kind regards,

 David



On 08/03/2019 10:50, SUSANA LAGE CAL via TRNSYS-users wrote:
Dear everybody 

I am in the process of calculating the energy demand of a building, by employing type 56.

Internal windows and glass doors are relevant in my house´s adaptative thermal behaviour. That is why I have included both of them in  Google Sketchup - Plugin TRNSYS 3D drawing.

But, unfortunately, once the  idf file is imported, I open Trnbuild to edit the building and I find that most of internal windows and also some of the external ones do not show up at the correspondent thermal zones.

Adjacencies have been thorougly checked and the dck file has also been properly set. The simulation works OK and I have been able to get some results. All the windows are light blue in the Sketchup-Plugin Trnsys 3D file. And the internal ones have been drawn simetrically in both adjacent thermal zones.

¿Could you please give any useful tip to solve my problem? ¿Is there perhaps a maximum number of windows and I am surpassing it?

Best regards



SUSANA LAGE CAL

 

Departamento de Energía UNIOVI


_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org
-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
3 North Pinckney Street - suite 202
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com

http://www.tess-inc.com