[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Increasing the maximum allowed number of equations



Amir,
  In order to increase the maximum allowable number of equations you need to recompile the TRNDll having modified the appropriate line in the file TrnsysConstants.f90:

Integer, Parameter :: nMaxEquations       =     500  ! Maximum number of equations                                  500

  If you do not have access to a Fortran compiler, please let me know how many equations you need and I can recompile one for you.
Kind regards,
 David




On 5/18/2014 01:28, Amir Nashed wrote:

Dear TRNSYS users,

 

Does anyone know how to increase the maximum allowable number of equations in TRNSYS?

 

I understood from a previous TRNSYS discussion that the problem is that I exceeded the number of allowable operators rather than the number of equations especially that I am simulating a certain process at different operating conditions using polynomial equations so there are lots of operators (and equations as well).

 

Thank you

 

Regards,

Amir Nashed

PhD Candidate

School of Renewable Energy and Photovoltaic Engineering

University of New South Wales

Phone:+61405979282

Email:a.nashed@unsw.edu.au

 



_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://mailman.cae.wisc.edu/listinfo/trnsys-users

-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
22 North Carroll Street - suite 370
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com

http://www.tess-inc.com