Re: [TRNSYS-users] Type 107 - Data File problem



Nicolàs, from personal experience and the number of related posts to this list, I think anyone who uses this type encounters the same difficulty and confusion! Personally, under time pressure, I used two approaches. The first is to create a very poor approximation by simply using the data file provided or creating a simpler data file with constant performance over a wide range of data. The data file format itself isn’t that complicated (two four-variable functions). The second approach that I am currently trying is to model the generator, absorber, and cond/evap coils with the auxiliary heater/cooler types (Type 92, 6).  It would be extremely useful to have an a wider range of data files, a simpler chiller model, or at least a walkthrough of creating a data file, at least to get something in the right order of magnitude as a first approximation . Hint hint @ developers!

 

Sorry I can’t help more,

 

Marcus

 

MARCUS JONES, MSc

Energy Department

Sustainable Building Technologies

 

AIT Austrian Institute of Technology

Österreichisches Forschungs- und Prüfzentrum Arsenal Ges.m.b.H.

Giefinggasse 2 | 1210 Vienna | Austria

T +43(0) 50 550-6387 | M +43(0) 664 210 24 15 | F +43(0) 50550-6598

marcus.jones@ait.ac.at | http://www.ait.ac.at

FN: 165088b HG Wien | UID: ATU46577208 This email and any attachments thereto, is intended only for use by the addressee(s) named herein and may contain legally privileged and/or confidential information. If you are not the intended recipient, please notify the sender by return e-mail or by telephone and delete this message from your system and any printout thereof. Any unauthorized use, reproduction, or dissemination of this message is strictly prohibited. Please note that e-mails are susceptible to change. Österreichisches Forschungs- und Prüfzentrum Arsenal Ges.m.b.H. shall not be liable for the improper or incomplete transmission of the information contained in this communication, nor shall it be liable for any delay in its receipt.

 

From: Nicolàs Rey [mailto:reynicolas84@gmail.com]
Sent: March 4, 2010 7:36 PM
To: trnsys-users@cae.wisc.edu
Subject: [TRNSYS-users] Type 107 - Data File problem

 

Dear TRNsys users,

I have a problem with type 107, the absorption chiller. In the Data file folder of TRNsys installation there is only one data file which can be used with this type. The problem is that I need to utilize the hot water with a temperature in a different range, and not only between 108.89 and 116.11 °C , the range of the data available.

Should I use data available on the internet? And if so, What’s the procedure to use them? I checked in the Mathematical reference but it is not so clear.

If someone of you could give me some help, I would be really grateful , because I need to use this file for my master thesis ( upon solar cooling) and I don’t have so much time!

Best regards,

 

Nicolàs Rey