Re: [TRNSYS-users] Problem with an input



Dear Samir,

Maybe you will have to connect "Batt froide CTA hbgt so" inputs directly with Type33 (Psychometric Type) . In this way, you will connect : - Type33 output2 (Wet Bulb Temperature) with Type32 Input 2 (Inlet Wet Bulb Temperature),
and
- Type33 output 7 (Dry Bulb Temperature) with Type32 Input 1 (Inlet Dry Bulb Temperature)

I can't test if it works or not, because I haven't the appropriate *.bui file to run the simulation. But try to do that, and tell me if it works.

King regards

Adrien


Chehal, Samir a écrit :

Dear Trnsys users,

I have a problem with my connection: input 1 of “Batt froide CTA hbgt so” is not correct and I don’t know why.

The message error is:

*** Fatal Error at time : 1.000000

Generated by Unit : 17

Generated by Type : 32

TRNSYS Message 103 : The TRNSYS TYPE checking routine has found an inconsistency in the specified component between the input file and the information expected by the Type

Reported information : An illegal INPUT value has been reported by the model. The model has reported that Input 1 is the problem - but this may not be the case. Please check the component configuration.

<<Wizard25.tpf>>

Best Regards

=========================================================

NOTICE - This communication may contain confidential and privileged
information that is for the sole use of the intended recipient. Any viewing,
copying or distribution of, or reliance on this message by unintended
recipients is strictly prohibited. If you have received this message in
error, please notify us immediately by replying to the message and deleting
it from your computer.

=========================================================
------------------------------------------------------------------------

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@engr.wisc.edu
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users

--

***************************************************************
Adrien JEZEQUEL	
Ingénieur en Simulations Dynamiques
ITF (Ingénierie Tous Fluides)
87, route de Chambéry
73230 ST ALBAN EN LEYSSE
FRANCE
Tel: 04.79.75.00.29
Website: www.itf.biz
Mail : a.jezequel@itf.biz