Dear Mohammad, I’d recommend you to read section
5.2.3.4. Outputs of the multizone building docu to find out how to add outputs. NType 9 – RELHUM - gives the relative Humidity NType 2 - QSENS - gives sensible energy demand (positive values are cooling) NType 12 – QSOLTR – gives total solar radiation transmitted through all external windows of an airnode Best _________________________________________________________________________________________________ Jakob Merk TRNSYS Software Team
Curiestraße 2 70563 Stuttgart Fax: +49 711 67976-11 Web: www.trnsys.de
Von: TRNSYS-users [mailto:trnsys-users-bounces@lists.onebuilding.org]
Im Auftrag von Mohammad Vahid via TRNSYS-users Dear all, I'm simulating a building with the help of the Building wizard of the software. The only output that I can get is the temperature changes
and it seems to be correct. My question is, how can I see the humidity changes in the building, Q gained from the sun, and the cooling load of the cooling system. Thanks in advance, Masih |