Without detailed measured data, or a CFD study of the tank in question, I would set the inversion flow rate input to -100, signifying that the inversions should be eliminated thoroughly at the end of each timestep.
Jeff
---
Jeff Thornton President - TESS LLC 22 N. Carroll Street, Madison WI USA 53703 Office: (608) 274-2577 Fax: (608) 278-1475 www.tess-inc.com E-Mail: thornton@tess-inc.com
On 05/20/2015 11:25 am, Anas Majdouli wrote:
Hi TRNsys community,
I am working on a DHW simulation using Type 534. The file is attached to this email.
I would like to know how to choose a value for "Inversion Mixing Flowrate", which is an input for Type 534.
I randomly chose 100 kg/hr, but I would like to know how to calculate this flowrate or how to choose it.
Thanks in advance.
Yours Sincerely,
Anas MAJDOULI
_______________________________________________ TRNSYS-users mailing list TRNSYS-users@lists.onebuilding.org http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org