[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Various configuration in Type-997



Sanjeev,
  The parameters of the Type describe the pipe layout so yes, you would have to change various parameter values in order to go from modeling a single straight pipe to modelign a single or a double serpentine pipe. I would recommend that you refer to the Type997 documentation, which can be found in ..\Trnsys17\Tess Models\Documentation\04-GHPLibraryMathematicalReference.pdf
regards,
 David
 

On 5/6/2015 10:39 AM, SANJEEV JAKHAR wrote:
Dear sir,
In Type 997 it is mention that it can be used for various configuration like serpentine double serpentine etc.
I have simulated the model for single pipe. I would like to know how to proceed for serpentine and double serpentine cases. Do I have to change in any parameter to make serpentine case.
Thanks & Regards,
Thanks & Regards,

Sanjeev Jakhar
Research Scholar

Center for Renewable Energy and Environment Development (CREED)
Mechanical Engineering Department
Birla Institute of Technology & Science, Pilani
Rajasthan - 333031


_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org