[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Various configuration in Type-997



Re: Type997: The model allows you to tell each pipe where it's inlet fluid is coming from and the direction of flow.  For a serpentine of 5 pipes, you would specify the flow pattern as:

Pipe 1:  Inlet=0 (Connected as an input), Direction=1

Pipe 2: Inlet=1 (From Pipe 1), Direction = 2

Pipe 3: Inlet=2 (From Pipe 2), Direction = 1

Pipe 4: Inlet=3 (From Pipe 3), Direction = 2

Pipe 5: Inlet=4 (From Pipe 4), Direction = 1

 

Jeff

 ---

Jeff Thornton
President - TESS LLC
22 N. Carroll Street, Madison WI USA 53703
Office: (608) 274-2577  Fax: (608) 278-1475
www.tess-inc.com
E-Mail: thornton@tess-inc.com

On 05/06/2015 10:39 am, SANJEEV JAKHAR wrote:

Dear sir,
In Type 997 it is mention that it can be used for various configuration like serpentine double serpentine etc.
I have simulated the model for single pipe. I would like to know how to proceed for serpentine and double serpentine cases. Do I have to change in any parameter to make serpentine case.
Thanks & Regards,
Thanks & Regards,

Sanjeev Jakhar
Research Scholar

Center for Renewable Energy and Environment Development (CREED)
Mechanical Engineering Department
 
Birla Institute of Technology & Science, Pilani
Rajasthan - 333031

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org