[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] type 1288 : evacuated collector or linear Fresnel



Type 1288 can model a host of collector technologies with 2-dimensional incidence angle modifiers - including evacuated tubes and Fresnel collectors.  There is nothing wrong with the installation.

Jeff Thornton
TESS

Sent from my iPhone

On Apr 1, 2015, at 4:56 PM, Nidal Abdalla <nidalabdalla@yahoo.com> wrote:

Dear All

I am using TRNSYS 17.02 with TESS. I am trying to use evacuated tube collector type 1288, but I found that Linear Fresnel Collector has also type number 1288 . Both components use the same source code. I copy the proforma of these components as follow:

"Generic Solar Collector Model Using the EN12975-2 Efficiency Approach - 2D IAMs
Tess Models\SourceCode\Type1288.f90"
 
"Linear Fresnel Collector using the EN12975-2 Efficiency Approach
Tess Models\SourceCode\Type1288.f90"
 
My question is :  Which component uses the correct source code?
Do you think that this problem appeared due to trouble in installing TESS in my PC?

Best regards

Nidal Abdalla

NERC - Amman - Jordan

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org