Dear TRNSYS users,

 

When opening a building (created with TRNSYS17.0) located in the southern hemisphere with TRNBuild (from TRNSYS17.1), the following error appears :

 

UNDEFINED WALL ORIENTATION

N_0_90

 

To overcome this error, you have to add HEMISPHERE SOUTHERN before the line starting with « orientation » in the B17 file.

 

*  O r i e n t a t i o n s

*----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

HEMISPHERE SOUTHERN

ORIENTATIONS N_0_90 S_180_90 E_270_90 W_90_90 H_0_0

*

*++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++

 

This problem seems to be due to the new feature of T17 dealing with hemisphere choice in TRNBUILD.

 

Sébastien Thomas
Assistant - Doctorant

Université de Liège
Arlon Campus Environnement
Equipe BEMS   - Building Energy Monitoring and Simulation -
185, Avenue de Longwy
B-6700 ARLON


  Tel: 32-(0)63-230 982
  Fax: 32-(0)63 230 800
  email: sebastien.thomas@ulg.ac.be
  WEB: http://www.bems.ulg.ac.be

 