Karol,
  We are working on a solution. The error seems to be dependent on what computer the simulation is being run on and on what compiler we use to create the DLL. For the time being, the workaround seems to be to use a timestep that conforms to 1/(2**n) where n is an integer. Please try using a timestep of 0.125 and let me know if that works. We will get a patch released as soon as possible with an actual fix.
Regards,
 David


On 8/22/2012 07:54, Karol Bandurski wrote:

Dear all

 

I would like to change ‘Simulation start time’ from 0 to eg. 2880 hr, my time step is 10 min – attached PICTURE_1

 

The problem is that when I set it, I get error from Type 15:

‘Unable to correctly read from the supplied data file - please check the file and re-run the simulation.’

 

I found response of Matt Duffy related to this issue:

https://mailman.cae.wisc.edu/pipermail/trnsys-users/2011/007369.html

 

but I don’t understand it.. I have changed my setting as you can see on attached PICTURE_2 and error occurs again.

 

Could you help me?

 

Regards,

Karol

------------------------------------------------

Karol Bandurski MSc.

Institute of Environmental Engineering

Poznan University of Technology

www.ee.put.poznan.pl

www.put.poznan.pl

 



_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://mailman.cae.wisc.edu/listinfo/trnsys-users

-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
22 North Carroll Street - suite 370
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com