Michael, I have run into this problem as well, particularly in Trnsys16 and I was not ever able to resolve it. In the end, I had to increase my flowrate through the floor enough (or segment the floor enough) so that the flow rate I was giving got above that threshold. My suspicion is that Type56 calculates the required minimum flow at one temperature and then corrects the actual flowrate for some temperature dependent property during the simulation. If your example is simple enough and you are willing, please send it our way so that we can try and track down the cause! Best, david On 6/18/2012 16:24, Michael Döbele wrote: Dear TRNSSYS User, -- *************************** David BRADLEY Principal Thermal Energy Systems Specialists, LLC 22 North Carroll Street - suite 370 Madison, WI 53703 USA P:+1.608.274.2577 F:+1.608.278.1475 d.bradley@tess-inc.com http://www.tess-inc.com http://www.trnsys.com |