Carlos, I have been getting this error too. My first "fix" was to change the error message to say that it may be a problem with either Type66 or Type56. Not much of a fix at all. I think the cause of the error is that when running from Studio and TRNEdit, TRNBuild gets called to process the *.b17 file and generate the *.bld, *.trn, and *.inf files. When called from TRNSED, however, the call to TRNBuild is bypassed and Type56 uses existing (already processed) *.bld, *.trn, and *.inf files. I managed to avoid the error by changing the "error" to a "warning" in my version of callProgram. This is just a workaround for TRNSED though; we are currently working on a permanent solution with Transsolar. Kind regards, David On 9/29/2011 14:50, torres.carlos-moises@lte.ireq.ca wrote:
-- *************************** David BRADLEY Principal Thermal Energy Systems Specialists, LLC 22 North Carroll Street - suite 370 Madison, WI 53703 USA P:+1.608.274.2577 F:+1.608.278.1475 d.bradley@tess-inc.com http://www.tess-inc.com http://www.trnsys.com |