Hi trnsys users,

I am using type16c to get diffuse rad from global data radiation. But type56 needs angle of incidence on horitzontal, and I don't know how to get angle of incidence on horitzontal because this type doesn't give it as an output. Does anybody know how I can get it?

Thanks in advance

Laia


En/na Matt Duffy ha escrit:

Dear Bastien,

"Time of last data read" and "Time of next data read" need to be connected from your external data reader, Type9, to your Type16 radiation processor, respectively. I am not 100% sure why - most likely a historical or fortran reason, but please make sure to connect those.

Best regards,

Matt Duffy



----- Original Message -----
From: "Bastien GARBAY" <garbay@enertech.fr>
Sent: Thu, May 20, 2010 2:36
Subject: [TRNSYS-users] Type 16c_Solar Radiation Processor

Dear all,
 
I would like to estimate the solar radiation on a tilted surface with Type 16c by choosing Mode 2 (Total radiation surface on a horizontal surface, ambient temperature and relative humidity datas are known). These  threes datas were measured with a step time of 10 minutes from November until Februar. I want to calculate the effective radiation on a northern and a southern orientation, in order to estimate the effective solar gains with a step time of 10 minutes.
 
I can't obtain correct results because I think I don't understand the inputs 4 and 5 of Type 16c. What does "Time of last data read" and "Time of next data read" mean?
Is it possible to use this type with a timestep of 10 minutes but with measures on only 4 months (not a complete year)?
 
Thanks for your help and your answer!
 
Bastien

 

 

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users
  

_______________________________________________ TRNSYS-users mailing list TRNSYS-users@cae.wisc.edu https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users

--
Laia Cases
Unitat de Condicionament Tèrmic
iMat - Centre Tecnològic de la Construcció
lcases@imat.cat
www.imat.cat

Wellington 23  ·   E-08018 Barcelona
T +34 93 553 97 95
F +34 93 553 97 96
Imprimiu aquest document només si és necessari