Hello Samar, the totally quantity of geosurf in every space of all the walls must be equal to 1. So for the ceiling, must be 0, for the wall facing the north also 0, for the ground can be 0.5 and for the rest of the walls you can divided for the rest. In chapter 6 (Multizone Building) you can found more information. Laia En/na Samar Jaber ha escrit: Dear Sir/Madam; I am facing a problem that I have cooling load during winter season. I doubt that geosurf did this unlogical results. I would you greatful if some body tell me the exact amount for geosurf parameters in TRNSBuilt for south, East, North and West walls. Also, for the windows. Also, if somebody have an idea or comments on this problem .. please let me know your suggestions and comments. Thank you and Best Regards, Samar ---------------------------------------------------------------- This message was sent using IMP, the Internet Messaging Program. _______________________________________________ TRNSYS-users mailing list TRNSYS-users@cae.wisc.edu https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users --
|