Hello Samar,

the totally quantity of geosurf in every space of all the walls must be equal to 1. So for the ceiling, must be 0, for the wall facing the north also 0, for the ground can be 0.5 and for the rest  of the walls  you can  divided  for the rest. In chapter 6 (Multizone Building) you can found more information.

Laia

En/na Samar Jaber ha escrit:
Dear Sir/Madam;

I am facing a problem that I have cooling load during winter season. I doubt
that geosurf did this unlogical results.

I would you greatful if some body tell me the exact amount for geosurf
parameters in TRNSBuilt for south, East, North and West walls. Also, for the
windows.

Also, if somebody have an idea or comments on this problem .. please let me know
your suggestions and comments.

Thank you and Best Regards,
Samar






----------------------------------------------------------------