Roberto,
It depends on the model but usually, the initial temperatures are set
in the Derivatives tab of the proforma, one temperature for each node.
Also make sure that you correctly fill in the field on the Derivatives
tab that usually asks about how many nodes there are in the tank.
Best,
David
rgaray@labein.es wrote:
Hello all,
I´m woirking with fluid storage
tanks,
for a solar heating system for residential buildings. My system
simulates
quite well, but i still have a small problem. How can I set the initial
temperature of a storage tank?
In my simulations it starts always
at
0ºC so it doesn´t work as it should for the first 2-3 days.
any help would be appreciated.
Thank you.
--------------------------------------------------------------------------