Javier,
The solar constant parameter in Type16 is the amount of solar radiation
falling on a 1 m2 surface outside the earth's atmosphere. There are a
number of different estimates of this amount dating back to various
research projects before the birth of TRNSYS. If you are getting only 6
warnings about radiation exceeding extraterrestrial during the course of
your simulation, I would not worry too much about it. The math and sun
earth geometry can cause such calculation. If you are getting hundreds of
those warnings then that is a good indication that there is something
incorrect about your input file.
Kind regards,
David
At 05:21 3/28/2006, javier mota wrote:
HALO.
I AM javier mota from 3i-ingenieria, madrid.
we have installed a radiaction register in hellin, a city in albacete,spain.
i am studying the data with a data reader and a radiation processor.
i have data from 26-nov to 21 march and i found i have an error "the beam
radiation excedeed the extraterrestrial radion forr 6 time steps."
I am running simulation with a time step of 10 minutes, data reader has data
at intervals of 10 minutes.
I have looked all the parameteres and all lokk ok.
but i have a doubt about the solar constant. 4871 kj / h m2 is the default
value in tyrnsys.
but it is a parmeter value.so i would be able to change this value.
but it is called solar connstant, contant mean it is a fixed value.
so, for this city in sapin, hellin, neqar albacete, the solar constant may
be a parameter that a should change to another value?
thanks in advance.
_________________________________________________________________
Moda para esta temporada. Ponte al día de todas las tendencias.
http://www.msn.es/Mujer/moda/default.asp
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@engr.wisc.edu
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users
****************************************************************************************
Thermal Energy System Specialists (TESS), LLC
David BRADLEY 2916 Marketplace Drive - Suite 104
Partner Madison, WI 53719
Phone: (608) 274-2577 USA
Fax: (608) 278-1475
E-mail: bradley@tess-inc.com
Web Pages: http://www.tess-inc.com and http://www.trnsys.com
"Providing software solutions for today's energy engineering projects"
****************************************************************************************
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@engr.wisc.edu
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users