Re: [TRNSYS-users] Type 177 dll error



Victoria,

 I don't have any experience with Dr Albers model. However, if the model is compiled as a 32-bit dll and you are using Trnsys18 in its native (64-bit format) that would explain the error. Likewise if Dr. Alber's model is compiled as a 64-bit dll and you are using a 32-bit Trnsys (v17 or the 32-bit version of v18) then you would again expect such an error. All of the pieces have to be compiled the same.

kind regards,

 David




On 01/17/2022 16:18, Victoria Sarai Amador Barraza via TRNSYS-users wrote:
Hello everyone, 

I am trying to use the type 177, wich  simulates single staged H2O/LiBr-absorption chillers. This type was developed by Dr.-Ing Jan Albers at the Institut für Energietechnik. Downloaded from: http://www.eta.tu-berlin.de/menue/mitarbeiter_innen/wimi/albers/

The thing is that whenever I try to run a simulation, an error occurs. A message appears indicating that the dll has not been found in the UserLib. I have already copied the dll to the respective directories but this error still shows. 

Has anyone worked with this type before? How can I run a simulation with it? 

Thanks,
Victoria