[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[TRNSYS-users] 10 min interval weather data (TYPE 9 & 16)




I am using 1 hr and 10 min weather data for the same location and year but my results are very different.  i think there is a problem in TYPE 9, 16 and simulation time step setting while i use 10 min interval weather data. with 1 hr interval everything is ok.

1- TYPE 9 i and using the Time interval of data 0.1667
2- simulation card time step   0.1667
3- Type 16 is connected to 99th and 100th parameter of the Type 9. 

AM i doing something wrong.???
--
Adnan Rasheed
Post-doc Research Fellow
Kyungpook National University
Daegu, South Korea.
+82-102762-0105

Mailtrack Sender notified by
Mailtrack 06/29/20, 05:45:49 PM