[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Photovoltaic I-V P-V characteristics curves



Tommaso,

 Which version of TRNSYS are you using? There have been some bug fixes to the PV models recently with the most recent ones in the v18.2 release.

kind regards,

 David


On 05/22/2020 15:45, Tommaso Orazi via TRNSYS-users wrote:
Hi,

Is TRNSYS reliable when simulating characteristic curves of solar
panels? (I-V and P-V)

I am trying to simulate the curves for a module at STC conditions but
when I compare them to the the ones on the producer datasheet, they
are way off. Particularly the Voc and Pmax are not as they should be.

For the five parameters model I used the suggested tool PV_REF_PARAMS,
which I don't trust much and seems very unstable, and also tried to
compute myself the parameters.

I followed the provided example for IV curves.

Kind regards

Tommaso
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org
-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
3 North Pinckney Street - suite 202
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com