[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [TRNSYS-users] Integrator Type 24
Umer,
If your simulation starts at hour zero then your choice doesn’t matter. If your simulation starts on February 1st for example and you choose absolute then the first year will reset on Jan 1 and the first line in the output file will be for 11 months of data. If you choose relative it will reset on Feb 1. Make sure your printer is set up the same way.
Jeff - TESS
Sent from my iPhone
> On Sep 6, 2019, at 4:01 AM, UMER SALEEM via TRNSYS-users <trnsys-users@lists.onebuilding.org> wrote:
>
> Hello everyone,
> For estimation of annual generated energy i am using Integrator "Type 24".
> parameters chosen: 1) Integration period: 8760
> 2) Relative or absolute start time:1
> Question is how to choose relative or absolute start time. ?
> Output result will be simple addition of overall generated energy through the year.?
> _______________________________________________
> TRNSYS-users mailing list
> TRNSYS-users@lists.onebuilding.org
> http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org