Most fan models take a rated flow rate as a parameter and a control signal as an input. These two values are multiplied together to set the fan outlet flow rate. In a way, this is the same as giving the fan an inlet variable mass flow rate provided that you have chosen a variable speed fan model where the control signal can vary between 0 and 1. There is a fan model in the TESS Hydronics library (Type744) where you truly do set the inlet mass flow rate directly as an input to the model. kind regards, David
On 08/23/2019 07:38, Waqas Ahmad via
TRNSYS-users wrote:
-- *************************** David BRADLEY Principal Thermal Energy Systems Specialists, LLC 3 North Pinckney Street - suite 202 Madison, WI 53703 USA P:+1.608.274.2577 F:+1.608.278.1475 d.bradley@tess-inc.com http://www.tess-inc.com http://www.trnsys.com |