Karol, for surface outputs including balance 906 “inside” relates to the face of the surface facing towards the selected zone. Front/Back is used to assign the construction correctly only. Kind regards, Marion -----------------------------------------------------------------------------------------------------------------------------------------------------------
Dipl.-Ing. Marion Hiller t:
+49.711.67976.0 f:
+49.711.67976.11 www.transsolar.com/ Amtsgericht Stuttgart - HRB 23347
/ Steuernummer: 99073/00911 / USt-IdNr.: DE 152272639 Von: TRNSYS-users <trnsys-users-bounces@lists.onebuilding.org>
Im Auftrag von Karol BANDURSKI via TRNSYS-users Dear Expert, I have generate balance B6 for a few walls. The equation components, among others, are heat fluxes on outside and on inside surface of the wall. When exterior wall is consider I assume that outside surface=exterior surface. But in the case of interior wall which surface is outside and which inside? It depend on front/back setting or zone for which balance of the wall has been set? Looking on results it seems to me that it is set
randomly… Kind regards, -------------------------------------------------------------------- Karol BANDURSKI M. Sc. Faculty of Civil and Environemntal Engeneering Division of Heating, Air Conditioning and Air Protection Poznan University of Technology www.put.poznan.pl/~karol.
bandurski https://www.researchgate.net/profile/Karol_Bandurski |