Re: [TRNSYS-users] trnedit-empty excel files



Dear David,
Thank you for your kind responce.
I solved my problems with trnedit.
I found two errors:
1) two identical logical numbers were associated with the different weather data external files
2) after the command ASSIGN there was not a blank space.
Now my 8232 simulations were developed.
Unfortunately, I had to divide my combinations in two groups of 8232 simulations because an error was noticed me after 10000 dck files created.
I did not understand the reason
Best regards
Domenico

Il Mer 24 Apr 2019, 18:30 David BRADLEY <d.bradley@tess-inc.com> ha scritto:

Domenico,

  I think you'll need to send the *.dck and any other files needed in order to run the project to your distributor for assistance. If you aren't sure who to contact, please email me directly and I can point you in the appropriate direction.

kind regards,

 David


On 04/23/2019 17:37, Domenico Mazzeo wrote:
Dear all,
I have made a parametric simulation, but the excel files in output are all empty.
I noticed this message in my log file:
Simulation log for: "C:\SIM\SIMULAZIONE1.dck"
 
*** Notice at time        :         0.000000
    Generated by Unit     : Not applicable or not available
    Generated by Type     : Not applicable or not available
    Message               : The TRNSYS Executable (TRNExe.exe) and main DLL (TRNDll.dll) are located in "C:\TRNSYS17\EXE"
 
*** Fatal Error at time   :         0.000000
    Generated by Unit     : Not applicable or not available
    Generated by Type     : Not applicable or not available
    TRNSYS Message     71 : An ASSIGNED logical unit number is already in use, either by the TRNSYS kernal or by a Type
    Reported information  : Logical Unit 117
 
*** Notice at time        :         0.000000
    Generated by Unit     : Not applicable or not available
    Generated by Type     : Not applicable or not available
    TRNSYS Message    503 : Just before reporting the error while processing the TRNSYS input file, the TRNSYS processor was performing the task listed in the reported information line below.
    Reported information  : Processing the keyword: ASSIGN
 
*** Fatal Error at time   :         0.000000
    Generated by Unit     : Not applicable or not available
    Generated by Type     : Not applicable or not available
    Message               : Errors found while processing the TRNSYS input file.
 
*** Simulation stopped with errors
    Total Notices         :         2
    Total Warnings        :         0
    Total Fatal Errors    :         2

Can you help me?
best regards

--
Logo Unical
Domenico Mazzeo (Ingegnere Energetico) 
Ph.D. Ing. Domenico Mazzeo
Dipartimento di Ingegneria Meccanica, Energetica e Gestionale - DIMEG
Università della Calabria
Via Pietro Bucci, 44C
87036 Rende (CS) Italy
e-mail: domenico.mazzeo@unical.it 
 Skype: domenicomazzeo87
-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
3 North Pinckney Street - suite 202
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com