TRNSYS only calls equations/constants if the constituent values change.  So if A = B + C, A is only re-evaluated if B or C change.  That's been true from version 16 on.

 

Jeff

 

---
Jeff Thornton President - TESS LLC 3 N. Pinckney Street, Suite 202, Madison WI USA 53703 Office: (608) 274-2577 Fax: (608) 278-1475 www.tess-inc.com E-Mail: thornton@tess-inc.com

On 10/24/2018 12:43 pm, Eric Peterson via TRNSYS-users wrote:

Hi David and/or Jeff,

 

I am now putting some constants followed by other constants defined by equations in the head of a *.dck file, but find it runs painfully slow.

 

Is there a way to ensure these are assessed once at the beginning of a simulation and are not assessed again?

 