Re: [TRNSYS-users] help needed regarding type99



Behzad,

  I would suggest that you try Type9 instead of Type99. It can be a little bit tricky to set up the parameters but I have found that with the data file, a Type9 and a Type65 that is just plotting what the data reader is outputting it isn't so hard. Type9 is a bit more flexible than Type99 in terms of the syntax that it reads. However, if you are reading solar radiation data then you'll need to also include a Type16 in your project and pass the data read by Type9 to the Type16 solar radiation processor.

kind regards,

 David



On 08/27/2018 05:45, up201700037 via TRNSYS-users wrote:
Dear users,

MY name is behzad shahzamanian from university of porto and i am seeking to apply weather user format-type99 in trnsys for introducing weather data from my experimental work done previously. I have difficuly how to use it for my case beacuse when i copy columns of variables from exel file of my data to the external file of type99, the simulation do not run and i receive an error for header syntax.

Best regards,
Behzad shahzamanian sichani
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org


--
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
3 North Pinckney Street - suite 202
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com

http://www.tess-inc.com