Shiva, Adjacencies between rooms on the same level and adjacencies between floors are treated the same way in TRNBuild. There are two important pieces of information in this case:
1. the wall construction. This is a list of the layers that make up the wall and their respective thicknesses. The wall construction is given a name (such as OUTWALL, GROUND, INTFLOOR) but these are just names; they do not carry any information about where the walls are located in resepect to other walls in the building. 2. the wall category specifies how the wall is positioned. The choices are EXTERNAL (meaning that one side of the wall will receive solar radiation), ADJACENT (meaning that there are zones (airnodes) on both sides of the wall, BOUNDARY (which means that one side of the wall faces the zone and the other faces a known (and specified) boundary condition, and INTERNAL (which means that the wall is entirely contained inside a single zone.
kind regards, David