The good news is that I can repeat the error with the Type 534 plug-in here. The bad news is that I don't know yet what's causing the issue. But when I simply specify the file in the Files tab of the proforma it runs fine here in TRNSYS. One thing I did notice was that you are using the setting for pure water. While that model is able to handle the temperature dependence of pure water, any downstream components likely cannot - which can cause energy balance issues. We recommend using the user-supplied properties option for this reason. We'll look into the Type 534 plug-in issue and report back.
Jeff
---
Jeff Thornton President - TESS LLC 22 N. Carroll Street, Madison WI USA 53703 Office: (608) 274-2577 Fax: (608) 278-1475 www.tess-inc.com E-Mail: thornton@tess-inc.com
On 04/13/2018 2:19 am, Schranzhofer, Hermann via TRNSYS-users wrote:
Hi Jeff,
It is just a simple example. Find attached the data file and the studio file. TRNSYS Version is 17.02.0004.
Thanks,
Hermann.
Von: TRNSYS-users [mailto:trnsys-users-bounces@lists.onebuilding.org] Im Auftrag von Jeff Thornton via TRNSYS-users
Gesendet: Donnerstag, 12. April 2018 18:34
An: TRNSYS users mailing list at OneBuilding.org <trnsys-users@lists.onebuilding.org>
Cc: Jeff Thornton <thornton@tess-inc.com>
Betreff: Re: [TRNSYS-users] Type 534
Send us your data file and we'll take a look at it. Which TRNSYS version are you using? Are you supplying the correct data file name on the files tabk of the proformaa?
Jeff
---
Jeff ThorntonPresident - TESS LLC22 N. Carroll Street, Madison WI USA 53703Office: (608) 274-2577 Fax: (608) 278-1475www.tess-inc.comE-Mail: thornton@tess-inc.comOn 04/12/2018 10:27 am, Schranzhofer, Hermann via TRNSYS-users wrote:
Hi,
I want to use the TESS storage tank model Type 534 for some simulations. What I need is stratified inlets. As far as I can see this is not possible with the proforma without plugin (the parameters are locked).
So I tried my best with the plugin. Configuration is no problem but if I press the OK button in the plugin a message appears telling me “Problem reading cycle number iteration”.
If I start the simulation anyway I get the Fatal Errors below:
*** Fatal Error at time : 0.000000
Generated by Unit : 6
Generated by Type : 534
Message : The storage tank model was unable to read the parameter values from the supplied data file. Please check the location and format of this data file carefully.
*** Fatal Error at time : 0.000000
Generated by Unit : Not applicable or not available
Generated by Type : 534
TRNSYS Message 105 : A TYPE was called in the TRNSYS input file but was either not linked into trndll.dll or was not found in an external dll. A dummy subroutine was called in its place. Please link the TYPE or remove it from the input file
Reported information : Reported by LinkCk
Is there any help for this problem?
Regards,
Hermann.
_______________________________________________TRNSYS-users mailing listTRNSYS-users@lists.onebuilding.orghttp://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org
_______________________________________________ TRNSYS-users mailing list TRNSYS-users@lists.onebuilding.org http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org