[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[TRNSYS-users] Type164a : Compressed Gas Reservoir



Hello,

I am modeling a 2 stages of air compressors with 2 compressed air reservoirs (Type164). And I have two questions regarding:


1)      Initial pressure of the Reservoir (Type164):

If we double click on type 164, we have access to the parameters, inputs and outputs. In my project, I want to fix the pressure of the reservoir (Pgas) to 1 bar. So I fixed PMAX=50bar (Para (2)) and PLEV_INI=0.02 (Input (4)) in order to P_INI = PLEV_INI*PMAX*1E5 equals 1 bar.

When I run the project, and I plot the result, I have at t=0 PGAS equals to zero (Pression.out).

It’s a bit confusing to initialize the pressure because there is a way_1 to fix P_ini (described above) and another way_2 to set initial output values (in my case, PGAS is OUT(2)). To be on safe side I put in the FORTRAN code (!set initial output value) OUT(2)=P_INI (And even with this, it does not work). So what way to take in order to initialize the pressure? Way 1 or 2 or both?

 

If I modify the FORTRAN (in order to set the initial output values), should I regenerate the Type164? And then rebuild new library? Or no need (just save)? If yes can you tell me step by step the process to rebuild the library, because I did it once not correctly (rebuild the library) and I damaged all the other types.

 

 

2)      Volume of the Reservoir (Type164):

By default the minimum volume of the reservoir is 1 m3. In order to change the interval (min, max) of the volume I did the following steps:

Right click on the type à Proforma à Variables à change the min for parameter 3 (VOL). Then click OK and close the Proforma after saving the changes. By this, the Type 164 is changed in the library also.

Problem: It does not work with the modified reservoir. In fact I repeated the same project [compressor and a reservoir (VOL=1 m3), where the system worked]. So I guess the steps to change the VOL interval are not correct.


Thank you for help

--

Ghady DIB

Doctorant

Laboratoire CETHIL UMR 5008
Groupe Energétique des Systèmes Thermiques et Frigorifiques (ESTF)

Département Génie Energétique et Environnement

INSA Lyon
France

Tel:+ (33) 6 33 52 96 74

Attachment: Pression.out
Description: Binary data

Attachment: Project17.tpf
Description: Binary data