Abdul, If you are using Trnsys18 and components from the standard
library then you can activate that component's simulation summary
report (use the "add report for this component" tool on the left
hand tool bar). The report will include the air conditioning
device's run-time. If you are using Trnsys17 and/or TESS library components then
you can define an equation that compares the power consumption of
the air conditioner to 0 and returns a 1 if the power is greater
than 0 as in: _onAC_ = GT(pAC,0) then you can integrate the value of onAC over the course of your simulation and you'll have the number of hours that it was active. kind regards, David