Send TRNSYS-users mailing list submissions to
trnsys-users@lists.onebuilding.org
To subscribe or unsubscribe via the World Wide Web, visit
http://lists.onebuilding.org/listinfo.cgi/trnsys-users- onebuilding.org
or, via email, send a message with subject or body 'help' to
trnsys-users-request@lists.onebuilding.org
You can reach the person managing the list at
trnsys-users-owner@lists.onebuilding.org
When replying, please edit your Subject line so it is more specific
than "Re: Contents of TRNSYS-users digest..."
Today's Topics:
1. PCMs integrated in walls or similar (Nika Gerbec)
2. Re: PCMs integrated in walls or similar (hotline)
3. Reflective insulation (Yossef Ibrahimi)
4. Re: Dynamic efficiency (Seyyed Tajdaran)
---------- Mensaje reenviado ----------
From: Nika Gerbec <nikagerbec@gmail.com>
To: trnsys-users@lists.onebuilding.org
Cc:
Bcc:
Date: Wed, 8 Nov 2017 09:56:55 +0100
Subject: [TRNSYS-users] PCMs integrated in walls or similarHelloI've been studying how PCM materials integrated in the walls can contribute to energy efficency of buildings. I am trying to simulate this with TRNSYS but I am missing a PCM type or modul for this.Does anybody has an experience working with PCMs and can share type with me?Thank you in advanceNika Gerbec
---------- Mensaje reenviado ----------
From: hotline <hotline@transsolar.com>
To: "TRNSYS users mailing list at OneBuilding.org" <trnsys-users@lists.onebuilding.org>
Cc:
Bcc:
Date: Wed, 8 Nov 2017 09:02:28 +0000
Subject: Re: [TRNSYS-users] PCMs integrated in walls or similar
Dear Nika,
what about TS nostand Type 399?
http://www.trnsys.de/download/
de/ts_type_399_en.pdf
Best
Jakob
______________________________
______________________________ ______________________________ ________
Jakob Merk M.Sc.
Transsolar Energietechnik GmbH
Curiestraße 2
70563 Stuttgart
Transsolar: KlimaEngineering- Technologien für energieeffizientes Bauen und Nutzerkomfort in Gebäuden
Stuttgart – München – New York – Paris
Geschäftsführer :Diplom-Ingenieur Matthias Schuler, Diplom-Ingenieur Thomas Auer, Diplom-Physiker Stefan Holst, Diplom-Betriebswirt Dieter Schnelle
Eingetragen beim Amtsgericht Stuttgart HRB 23347,
Steuernummer: 99073/00911,USt-IdNr.: DE 152272639
Von: TRNSYS-users [mailto:trnsys-users-bounces@
lists.onebuilding.org ] Im Auftrag von Nika Gerbec via TRNSYS-users
Gesendet: 08 November 2017 09:57
An: trnsys-users@lists.onebuilding.org
Cc: Nika Gerbec <nikagerbec@gmail.com>
Betreff: [TRNSYS-users] PCMs integrated in walls or similar
Hello
I've been studying how PCM materials integrated in the walls can contribute to energy efficency of buildings. I am trying to simulate this with TRNSYS but I am missing a PCM type or modul for this.
Does anybody has an experience working with PCMs and can share type with me?
Thank you in advance
Nika Gerbec
---------- Mensaje reenviado ----------
From: Yossef Ibrahimi <yossefibrahimi@yahoo.com>
To: "TRNSYS Users Mailing List at OneBuilding.org" <trnsys-users@lists.onebuilding.org>
Cc:
Bcc:
Date: Wed, 8 Nov 2017 10:34:50 +0000 (UTC)
Subject: [TRNSYS-users] Reflective insulationHi,I try to model a roof with an "air gap" and "reflective insulation", but It's not possible to specify the longwave emission and the absorptance coefficient for each layer (TRNSYS 17).Shall I create a zone with a height=air gap above the roof, and use the carachteristics of the reflective insulation for the back side of the roof and front side of this aditionnal zone ?Best regards,Yossef
---------- Mensaje reenviado ----------
From: Seyyed Tajdaran <stajdaran@brookes.ac.uk>
To: Jeff Thornton <thornton@tess-inc.com>
Cc: "TRNSYS users mailing list at OneBuilding.org" <trnsys-users@lists.onebuilding.org>
Bcc:
Date: Wed, 8 Nov 2017 10:52:11 +0000
Subject: Re: [TRNSYS-users] Dynamic efficiencyThat's brilliantThe thing I am just struggling to follow is, if for instance for a boiler the input value for the boiler efficiency is set and the Macro button is toggled, are we expecting the efficiency to stay fixed during the time? and how the macro is impleneted here. The problem is I can't find the documentation of Boiler's in 2017 version.On 7 November 2017 at 15:30, Jeff Thornton <thornton@tess-inc.com> wrote:Sadjad,Absolutely that's how TRNSYS works. TRNSYS models take time independent values called PARAMETERS and time-dependent values called INPUTS together to calculate the OUTPUTS from the model. The inputs can be from another model, set to a constant value, read from an external file, set by a function etc.We have several "heating unit" models and they differ on how they calculate the performance. Most read a performance data file that returns a value based on the inlet operating conditions.JeffTESS LLC
Sent from my iPhone
On Nov 7, 2017, at 3:40 AM, Seyyed Tajdaran via TRNSYS-users <trnsys-users@lists.onebuilding.org > wrote:Hello allI am looking into use TRNSYS for dynamic simulation. However, I am struggling to find out if the software actually works in a dynamic condition. To be specific I would like to know if the efficiency of a heating unit is calculated as a function of the relevant parameters (i.e. time, temperature, pressure)???Warm regards,Sadjad--Sadjad Tajdaran
PhD Candidate | Research Assistant
Oxford Brookes University, School of Architecture, Faculty of Technology Design and EnvironmentArchitectural Engineering GroupJP203, John Payne Building,Headington Campus, Gipsy Lane, Oxford, UK, OX3 0BP_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebu ilding.org --Sadjad Tajdaran
Research Assistant | PhD candidate
Oxford Brookes University, Faculty of Technology Design and EnvironmentArchitectural Engineering Group and DYNAMO Project GroupJP204, John Payne Building, Headington Campus, Gipsy Lane, Oxford, UK, OX3 0BPR201, R Building, Wheatley Campus, Wheatley, Oxford, OX33 1HX
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users- onebuilding.org
Attachment:
Active and passive PCM walls simulation-A_new_TRNSYS PCM-Type-Luis_J_Claros-Marfil-CONSTEC-2014.pdf
Description: Adobe PDF document