Which Type number are you using? But I'm not sure it matters what the pressure is on the plotter at time zero. No iterative calculations are being done at Time = 0 so other models will not be able to get this information from this type.
If your new type needs the initial pressure at time zero then simply ask for it as a parameter.
Jeff - TESS
Sent from my iPhone Dear all,
I am using
the Compressed Gas Storage and I am fixing an initial pressure.
My question
is the following: the term “initial values” means at Time = TIME0? But when I plot
the pressure Vs the simulation time, the pressure at T=0 is equal to zero.
--
Ghady DIB Doctorant
Laboratoire CETHIL UMR 5008
Groupe Energétique des Systèmes Thermiques et Frigorifiques (ESTF)
Département Génie Energétique et Environnement
INSA Lyon
France
Tel:+ (33) 6 33 52 96 74
|