Aditi,

It really depends on what performance data you have available for the solar collector you'll be using.  Type 71 and 538 use a quadratic efficiency equation and Type 1288 uses the 6 parameter model from the EN12975 standard.  Beyond that, Type 538 is somewhat similar to Type 71 but offers more features (outlet temperature control, impact of mass, etc.)

 

Jeff

 

---