Oriol, The *.tmf and *.bmp should be placed in a subfolder in the
..\Trnsys17\Studio\Proformas\ directory. The *.dll should be
placed in ..\Trnsys17\UserLib\ReleaseDLLs\. The *.for (source
code) is not relevant to running the component in the context of a
simulation. It is needed for reference and if you intend to make
changes to the component (in which case you would also need a
Fortran compiler). As a side note, there are different coding conventions for different Trnsys versions. If, when you run a simulation containing the component, you get an error saying that the component was not found in a DLL or could not be loaded the problem may be that the component was written for a different version of TRNSYS than you are running. kind regards, David
On 03/29/2017 03:08, Oriol Casal via
TRNSYS-users wrote:
-- *************************** David BRADLEY Principal Thermal Energy Systems Specialists, LLC 22 North Carroll Street - suite 370 Madison, WI 53703 USA P:+1.608.274.2577 F:+1.608.278.1475 d.bradley@tess-inc.com http://www.tess-inc.com http://www.trnsys.com |