Hello,

It is logic, but this value takes into account just the capacitance of the air. If you want to consider also the capacitance of the furniture, normally a plausible value could be 20 – 30 times the default capacitance.

 

Da: TRNSYS-users [mailto:trnsys-users-bounces@lists.onebuilding.org] Per conto di Ilyas KHELIFA KERFAH via TRNSYS-users
Inviato: mercoledì 25 gennaio 2017 23:32
A: TRNSYS users mailing list at OneBuilding.org <trnsys-users@lists.onebuilding.org>; hotline <hotline@Transsolar.com>; David BRADLEY <d.bradley@tess-inc.com>
Oggetto: [TRNSYS-users] capacitance- TRNBUILD-TRNSYS 17

 

Hello.

I have a question about the capacitance of TRNSYS zones.

I see in the TRNBUILD that the value by default to calculate the capacitance (volume of the pieces * 1.2). it's logic ?. thank you.