Thanks Katarzyna,

 

I may have misunderstood your configuration however it may be 0 because no sensible cooling or heating is being supplied to the building as you have ‘set as “off”. This is a free house model which may use no energy but be very uncomfortable.  

 

Try switching on a heating and cooling type and setting an appropriate set-points, capacity.


If that doesn’t work, send through your file and I’ll have a look.


Best regards,
Jeremy Osborne

 

Jeremy Osborne

Director

 

Energy Analysis & Engineering – Enabling innovation for a sustainable future

T: +61 2 8003 4323 | M: +61 4 000 63327 | E: jeremy.osborne@energyae.com

608 Harris St Sydney NSW 2007 Australia | http://www.energyae.com

 

Learn TRNSYS, faster

https://learn.trnsys.guru    

 

From: TRNSYS-users [mailto:trnsys-users-bounces@lists.onebuilding.org] On Behalf Of Katarzyna Palaszynska via TRNSYS-users
Sent: Tuesday, 13 September 2016 3:35 PM
To: trnsys-users@lists.onebuilding.org
Subject: [TRNSYS-users] Active layers

 

I prepared simulation of room. Active layers (TABS) are the only heat and cool equipment (no radiators or fancoil). I use type 56. In the room I've got infiltration, ventilation and gains defined. Heat and cool are set as "off". With this settings Q_SENS is always 0. What should I do to obtain the proper Q_SENS value?

Regards
Katarzyna