[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Type 16 (radiation processor)



Thank you very much Jaff for answering me. To solve a little more confusion, i need your kind attention. As I want to apply radiation data on my

 building by connecting TYPE 16 with TYPE 56 and gives there all the surface orientations. In a TYPE 56 there is no input to connect with solar 

radiation. If I add new inputs on the basis of my orientations and then attached all radiation output of TYPE 16 as an input in TYPE 56 does it will 

work? and give me the total solar energy gain inside???  

Regards
Adnan 

On Sun, Sep 11, 2016 at 3:18 AM, Jeff Thornton <thornton@tess-inc.com> wrote:
Use more than one Type 16 hooked up to the single Type 9.

Jeff Thornton
TESS

Sent from my iPhone

> On Sep 10, 2016, at 6:55 AM, adnan rasheed via TRNSYS-users <trnsys-users@lists.onebuilding.org> wrote:
>
> Hello everyone,
>
> My question is about TRNSYS type 9 (weather data reader) and type 16 (radiation processor). I am using feild weather data to apply to a building 3d model by using type 56. I have 17 surfaces (beacause of my roof design) in the model and type 16 only allows 8 surfaces to give output for,
>
> when i connect 3d model with type 15 (weather data reader and processor) it automatically connect 17 surfaces. But I cannot use type 15 because I need to use my own weather data in text file. How can I deal with that.
>
>
>
> Best regards
>
> Adnan
> PhD student
> _______________________________________________
> TRNSYS-users mailing list
> TRNSYS-users@lists.onebuilding.org
> http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org