Hello everyone,

My question is about TRNSYS type 9 (weather data reader) and type 16 (radiation processor). I am using feild weather data to apply to a building 3d model by using type 56. I have 17 surfaces (beacause of my roof design) in the model and type 16 only allows 8 surfaces to give output for, 

when i connect 3d model with type 15 (weather data reader and processor) it automatically connect 17 surfaces. But I cannot use type 15 because I need to use my own weather data in text file. How can I deal with that.   