[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] TBOUNDARY in Type-56



Joseph,

 In the template Type56 building file there is a BOUNDARY type wall and the temperature on the outside surface of that wall is an input variable called TBOUNDARY. If you did not use any walls of type BND_WALL then you can probably delete the TBOUNDARY input. Please note that the GROUND_FLOOR in the template building file obtains its back side temperature in the same manner from an input called TGROUND.

kind regards,

 David



On 08/04/2016 12:48, Joseph Oudi via TRNSYS-users wrote:
Hi all,

  Please can any one explain to me in details what this input
"TBOUNDARY" in type-56 means ??
  See attached file, thank you

Best regards,
Joseph.


_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org

-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
22 North Carroll Street - suite 370
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com

http://www.tess-inc.com