[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Real time readings into simulation



Type 9 is your best bet.  Make sure you provide the data in consistent time steps (no holes in the data, skipped steps etc.).  If you have solar radiation data be extremely careful and couple Type 9 with Type 16.  Refer to the manual and examples for good tips and tricks.

Jeff

Jeff Thornton
TESS
Sent from my iPhone

> On Mar 26, 2015, at 8:54 AM, Martin Berov <martber88@gmail.com> wrote:
> 
> Dear Trnsys users,
> 
> Is it possible to implement real time readings as input values into the simulation,  for example real time measuring temperature inlet/outlet collector temperatures and according this values to simulate the temperature change in the tank,  useful collector energy gain efficiency etc.. If it's possible, in few words  hat would be the procedure which Type should be used...
> 
> Thank you
> 
> Best regards
> Martin
>  
> _______________________________________________
> TRNSYS-users mailing list
> TRNSYS-users@lists.onebuilding.org
> http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org