Roberto,
  Can you give me some more information about what you mean when you say that you are checking the outputs of certain units? If you are looking at the output values that are displayed when you open a component in the Simulation Studio and look at its outputs tab then these will only ever show a constant value. That was a feature intended to give you an idea of the steady state output given the input initial values. When looking at simulation results you should be looking at the output files that are printed by whatever output producing devices you have in your simulation (such as Type25, Type65 (in its file writing mode), and Type933)
Kind regards,
 David



On 4/9/2014 10:17, Garay Martinez, Roberto wrote:

Dear Trnsys Users,

 

We´re trying to simulate a large system, comprising 100+ units in TRNSYS16. We have already undergone a TrnsysConstants modifications to allow for sufficient output & equation numbers.

 

At this moment, the project gets simulated and Trnexe tells us that the simulation has been completed successfully. However, the output of the units we’ve checked are constant and equal to their initialization values for all timesteps.

 

Any idea on this?

 

Thank you.

 

Roberto Garay Martinez

 

División Construcción Sostenible /

Sustainable Construction Division

 

TECNALIA
Parque Tecnológico de Bizkaia

C/Geldo s/n, Edificio 700

E-48160 Derio Bizkaia Spain

Tel.: +34 946 430 069

Mov.: +34 667 178 958

Fax:  +34 946 460 900

Roberto.garay@tecnalia.com

www.tecnalia.com

http://www.linkedin.com/in/robertogaray

 

Descripción: faldon_mail
Este mensaje puede contener información confidencial o privilegiada. Si no eres el destinatario de este mensaje, notifícaselo por favor al remitente y bórralo sin reenviarlo o guardarlo dado que está legalmente prohibido.
Mezu honek daukan informazioa isilpekoa edo pribilegiatua izan daiteke. Zuri zuzendua ez badago emaiozu, mesedez,  horren berri igorleari eta ezaba ezazu bidali edo gorde gabe, legalki debekatua dago eta.
This message may contain confidential, proprietary or legally privileged information. If you are not the intended recipient of this message, please notify it to the sender and delete without resending or backing it, as it is legally prohibited.

Por favor, piensa en el medio ambiente antes de imprimir este e-mail.

Mesedez pentsatu ingurugiroan e-mail hay imprimatu baino lehen.

Please, consider the environment before printing this e-mail.

 

 



_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://mailman.cae.wisc.edu/listinfo/trnsys-users

-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
22 North Carroll Street - suite 370
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com