[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Capacitance clarification in TYPE536



Dev,
  The capacitance should account for the thermal capacitance of the entire array (collectors, manifolds, fluid etc.). A single differential equation governs the array; there are not separate but coupled differential equations for the fluid and for the array itself. Since we do not have a second differential equation, we distribute the capacitance of the entire array into the number of collector nodes.
Kind regards,
 David
 

On 2/26/2014 09:57, Sharma Dev wrote:

Dear Admins,

 

Parameter 14 : Capacitance of Collector, is “Capacitance of a solar collector” or “Capacitance of the array of collectors” ?

 

My confusion arises from the fact that in variable details, it is specified as “The capacitance of the solar collector and fluid it contains” i.e Single collector. Whereas in source code, nodal capacity is calculated by dividing this parameter by the number of collectors (number of series * number in parallel ).  

 

Thanks

 

Dev Sharma

Institute for Renewable Energy

 

EURAC research

Institute for Renewable Energy
Via Luis-Zuegg 11, I-39100 Bolzano

t +39 0471 055 600

f +39 0471 055 699

dev.sharma@eurac.edu

www.eurac.edu

 

EURAC research

Legal Seat

Viale Druso 1, I-39100 Bolzano


This transmission is intended only for the use of the addressee and may contain confidential or legally privileged information.
If you receive this transmission by error, please notify the author immediately by mail and delete all copies of this transmission and any attachments.
Any use or dissemination of this communication is strictly prohibited by the "Privacy-Code", D.Lgs. 196/2003 and may lead to penal prosecution and liability for damages.

 

P Think before you print

 



_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://mailman.cae.wisc.edu/listinfo/trnsys-users

-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
22 North Carroll Street - suite 370
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com