Matthieu,
  One of the parameters of Type66 is the number of outputs that EES is going to provide. I can imagine that if you set that parameter to a value but then EES was passing back more than that number outputs, the error might be triggered.
Kind regards,
 David
 

On 11/26/2013 05:51, COSNIER Matthieu wrote:

Dear all,

I try to simulate an heating component modeled with ees software, in TRNSYS environment  by using type 66a (calling  ees routines).

The simulation works for few time steps but finally crash with the following error message:

 

“TRNSYS Message    129 : The referenced Unit has tried to set an Output value higher than the number of Outputs that the Type reserved for itself.”

 

Could someone explain me what it means?

 

Best regards

Matthieu