The Mathematical Description manual describes how Type 99 works. I would recommend starting there if you want to use Type 99.
Regards,
Tim
--- Timothy P. McDowell Executive Vice President Thermal Energy System Specialists, LLC 22 N Carroll St, Suite 370 Madison, WI 53703 608-274-2577
On 2013-03-08 12:04, jihad alaoui sosse wrote:
ok but you dont think that type 99 can do that !!!! and if the information i have (temp,horizental radiation ) is enough to simulate my building.
2013/3/8 <mcdowell@tess-inc.com>
Take a look at the RadiationProcessing.tpf example project in the Trnsys17_1\Examples\Weather Data directory.
Regards,
Tim
--- Timothy P. McDowell Executive Vice President Thermal Energy System Specialists, LLC 22 N Carroll St, Suite 370 Madison, WI 53703 608-274-2577On 2013-03-08 11:52, jihad alaoui sosse wrote:
if you have a tutorial to do that send it ti me please
2013/3/8 <mcdowell@tess-inc.com>
If you have the data in Excel, you should use Type9 to read your data and Type16 to calculate the solar radiation.
Regards,
Tim
--- Timothy P. McDowell Executive Vice President Thermal Energy System Specialists, LLC 22 N Carroll St, Suite 370 Madison, WI 53703 608-274-2577On 2013-03-08 11:44, jihad alaoui sosse wrote:
I do not know how to use a building knowing that I only have the following information (temperature, humidity, radiation global the horizontal) with the tmy reader knowing there are many as I have not1) is it possible to simulate my building just given withi mean how to use type 99
Thank you in advance.
--
Jihad Alaoui SosseIngénieur d'étude
Département Energie
Tél : O619162940 ;
Courriel : sys.energie@gmail.com
NOVEC, Filiale de CDG Développement - Groupe CDG
Angle Avenue Annakhil et Mehdi Ben Barka
Espace les Palmiers – Hay Riad – Rabat - MAROC
Site web : www.novec.maP Avant d'imprimer, pensez à l'environnement !
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://mailman.cae.wisc.edu/listinfo/trnsys-users
--
Jihad Alaoui SosseIngénieur d'étude
Département Energie
Tél : O619162940 ;
Courriel : sys.energie@gmail.com
NOVEC, Filiale de CDG Développement - Groupe CDG
Angle Avenue Annakhil et Mehdi Ben Barka
Espace les Palmiers – Hay Riad – Rabat - MAROC
Site web : www.novec.maP Avant d'imprimer, pensez à l'environnement !
--
Jihad Alaoui SosseIngénieur d'étude
Département Energie
Tél : O619162940 ;
Courriel : sys.energie@gmail.com
NOVEC, Filiale de CDG Développement - Groupe CDG
Angle Avenue Annakhil et Mehdi Ben Barka
Espace les Palmiers – Hay Riad – Rabat - MAROC
Site web : www.novec.maP Avant d'imprimer, pensez à l'environnement !