Hassan,
Please send me the *.lst file that is generated when you run the simulation and I'll see if I can find the problem.
Best,
David
On 11/9/2012 10:11, hassan bouhess wrote:
Dear all,
Whene i simulate the Type.460 in TRNSYS.16, i have this probleme in the lesting file, the probleme is i don't understand what means :
** Fatal Error at time : 0.000000
Generated by Unit : Not applicable or not available
Generated by Type : Not applicable or not available
TRNSYS Message 48 : The TRNSYS processor has reported that an unrecognized control card was found while trying to read the input file. This error can be caused by underspecifying a required number of items in the input file. For example, specifiying only 9 parameters after a "PARAMETERS 10" card has been read can cause this error. The line that caused this error is listed in the reported information below.
Reported information : TIME_REPORT
*** Fatal Error at time : 0.000000
Generated by Unit : Not applicable or not available
Generated by Type : Not applicable or not available
Message : Errors found while processing the TRNSYS input file.
Has anyone had this problem before?
I am very thankful for any suggestions how to solve this probleme. I have no other ideas so far.
Best
Hassan
_______________________________________________ TRNSYS-users mailing list TRNSYS-users@cae.wisc.edu https://mailman.cae.wisc.edu/listinfo/trnsys-users
-- *************************** David BRADLEY Principal Thermal Energy Systems Specialists, LLC 22 North Carroll Street - suite 370 Madison, WI 53703 USA P:+1.608.274.2577 F:+1.608.278.1475 d.bradley@tess-inc.com http://www.tess-inc.com http://www.trnsys.com
TRNSYS - the TRaNsient SYstem Simulation program The Solar Energy Lab at the University of Wisconsin - Madison, USA Le Centre Scientifique et Technique du Batiment, Sophia Antipolis, France Transsolar Energietechnik GmBH, Stuttgart, Germany Thermal Energy System Specialists, Madison Wisconsin, USA Release 16.00.0036 Listing file for: "D:\dossier bouhess hassan\trnsys16\type460\Type460.dck" *** Pre-Processing the TRNSYS EQUATIONs and CONSTANTs to check for fatal errors. *************************************************************** * CONTROL CARDS *************************************************************** *************************************************************** * CONTROL CARDS *************************************************************** *** Pre-Processing of EQUATIONs and CONSTANTs completed. no fatal errors found. *** Evaluating the EQUATIONs and CONSTANTs to determine their initial values. *** Finished evaluating the EQUATIONs and CONSTANTs and ready to begin processing the remainder of the TRNSYS input file. *************************************************************** * CONTROL CARDS *************************************************************** ! trnsys version VERSION 16 ! start, stop, step SIMULATION 0.0000000000000000E+00 1.7520000000000000E+04 1.0000000000000000E+00 ! integration, convergence TOLERANCES -1.0000000596046462E-04 -1.0000000596046462E-04 ! max iterations, warnings, trace limit LIMITS 30 30 31 ! integration solver method DFQ 1 ! width of output file WIDTH 80 ! solver, min relaxation, max relaxation SOLVER 1 *** Warning at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available TRNSYS Message 86 : You are using solver 1 but numerical relaxation factors for Solver 0 are specified. They will be ignored. Reported information : Not available ! nan debug statement NAN_CHECK 0 ! Overwrite debug statement OVERWRITE_CHECK 0 ! disable time report *** Fatal Error at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available TRNSYS Message 48 : The TRNSYS processor has reported that an unrecognized control card was found while trying to read the input file. This error can be caused by underspecifying a required number of items in the input file. For example, specifiying only 9 parameters after a "PARAMETERS 10" card has been read can cause this error. The line that caused this error is listed in the reported information below. Reported information : TIME_REPORT *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available TRNSYS Message 503 : Just before reporting the error while processing the TRNSYS input file, the TRNSYS processor was performing the task listed in the reported information line below. Reported information : Processing the keyword: OVERWRITE_CHECK *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available TRNSYS Message 503 : Just before reporting the error while processing the TRNSYS input file, the TRNSYS processor was performing the task listed in the reported information line below. Reported information : Processing the keyword: OVERWRITE_CHECK *** Fatal Error at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : Errors found while processing the TRNSYS input file.
Attachment:
Type460.log.log