[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Adding data file to Type 56



Hi Azeldin,

in Type 56 in set temperature you can instead of entering some value choose option input and make new input named for instance temperature. Then in simulation studio connect that input to the Type 9a which for external file uses txt file with your temperature values (this file should contain only temperatures, not time data). The txt file you can make by using excel file which you will save as csv file with comma and then rename in to the txt file. 


Regards,

Miroslava Kavgic

On 25 October 2012 12:02, Azeldin El-sawi <azeldin.elsawi@gmail.com> wrote:
Hi ;

Thanks for your attention


the project is:

1- one zone of building
2- I have data in file that is a source temperature obtained from another program which is needed to supply into zone (important part)

the data is temperature and time not weather file,

I need to model one zone with using whether file and the data file'

your help highly appreciated

Regards

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://mailman.cae.wisc.edu/listinfo/trnsys-users




--
Miroslava Kavgic Dipling, MSc
PhD Candidate
 
Bartlett School of Graduate Studies
University College London (UCL)
Central House
14 Upper Woburn Place
London     WC1H 0NN    UK
 
E-mail:miroslava.kavgic@gmail.com