Re: [TRNSYS-users] District Cooling Plant performance simulation Trnsys



Marco,
 My apologies for the delay in getting back to you. We have used TRNSYS on a few occasions to model central plants. We have relied heavily on the components in the TESS CHP library in most cases because that library contains a number of steam components such turbines, boilers, heat recovery steam generators, etc. The big advantage that TRNSYS has here is that central plants tend to be fairly unique in their design. As a result the flexibility of being able to build the system up out of its components pieces is highly useful. You could certainly come up with overall plant COP and energy consumption values. As far as autosizing is concerned, I think this would be harder. You would have to build up the configurations and specify equipment sizes and flow rates that are predetermined; TRNSYS does not have the ability to automatically and internally adjust equipment size.
Best,
 David


On 10/8/2012 08:26, marco.gangichiodo@climespace.fr wrote:

Hi all,

 

I would be very grateful to receive any useful information in regards to the use of Trnsys for simulating district cooling plants performance under a number of different variables in order to establish system COP, energy consumption and etc as well as to perform optimum design and integration of others components such as storage tank . Is it possible with Trnsys to perform plant sizing under different configurations  as well as the above ? Is it possible to perform such task, and if so has anybody in this forum undertaken such simulation?

 

Thanks in advance and hope to hear any news soon.

Kind Regards

Marco Gangi Chiodo

 

 

Marco Gangi Chiodo

Ingènieur d'études

Direction du Développement Technique

 


cid:image001.jpg@01CC160F.E386BB00

185, rue de Bercy

75012 PARIS

Tel   : 01 44 74 89 74

Fax  : 01 44 74 89 49

mailto:marco.gangichiodo@climespace.fr

 


___________________________________________________________________________
GDF SUEZ Mail Disclaimer : http://www.gdfsuez.com/disclaimer/disclaimer-fr.html

Before printing, think about the environment / Avant d'imprimer, pensez à l'environnement



_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://mailman.cae.wisc.edu/listinfo/trnsys-users

-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
22 North Carroll Street - suite 370
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com