Send TRNSYS-users mailing list submissions to
trnsys-users@cae.wisc.edu
To subscribe or unsubscribe via the World Wide Web, visit
https://mailman.cae.wisc.edu/listinfo/trnsys-users
or, via email, send a message with subject or body 'help' to
trnsys-users-request@cae.wisc.edu
You can reach the person managing the list at
trnsys-users-owner@cae.wisc.edu
When replying, please edit your Subject line so it is more specific
than "Re: Contents of TRNSYS-users digest..."
Today's Topics:
1. run simulation (use new component) (Eva gklezakou)
2. Re: run simulation (use new component) (Jeff Thornton)
3. Re: solar cooling (H2O/LIBR single effect absorption machine)
(Jochen Doell)
4. External data files for heat pump& absorbtion chiller
(Santeri Siren)
5. insertion of a balcony (Alessandro Rinaldi)
---------- Forwarded message ----------
From: Eva gklezakou<gklezakoue@gmail.com>
To: trnsys-users<TRNSYS-users@cae.wisc.edu>
Cc:
Date: Wed, 9 May 2012 21:11:02 +0100
Subject: [TRNSYS-users] run simulation (use new component)
Dear Sirs,
I am a beginner user of TRNSYS so I am not sure if I use it in the right
way. I want to use a new component which I receive but even though I copy
paste the *.dll file of the PCM component to the exe folder of TRNSYS and
the *.tmf to the proformas still have an error which says that " A TYPE was
called in the TRNSYS input file but was either not linked into trndll.dll
or was not found in an external dll. A dummy subroutine was called in its
place. Please link the TYPE or remove it from the input file".
Thank you.
Regards,
Eva
---------- Forwarded message ----------
From: Jeff Thornton<thornton@tess-inc.com>
To:<trnsys-users@cae.wisc.edu>
Cc:
Date: Wed, 09 May 2012 15:16:55 -0500
Subject: Re: [TRNSYS-users] run simulation (use new component)
**
The user-created DLL's don't go in the Exe folder. They go in the correct
spot in the UserLib directory (depends on whether the DLL was created as a
release version DLL or a debug-version DLL).
Jeff
---
Jeff Thornton
*President - TESS LLC*
*22 N. Carroll Street, Madison WI USA 53703*
*Office: (608) 274-2577 Fax: (608) 278-1475*
*www.tess-inc.com*
*E-Mail: thornton@tess-inc.com*
On 05/09/2012 3:11 pm, Eva gklezakou wrote:
Dear Sirs,
I am a beginner user of TRNSYS so I am not sure if I use it in the right
way. I want to use a new component which I receive but even though I copy
paste the *.dll file of the PCM component to the exe folder of TRNSYS and
the *.tmf to the proformas still have an error which says that " A TYPE was
called in the TRNSYS input file but was either not linked into trndll.dll
or was not found in an external dll. A dummy subroutine was called in its
place. Please link the TYPE or remove it from the input file".
Thank you.
Regards,
Eva
---------- Forwarded message ----------
From: Jochen Doell<jochen.doell@ise.fraunhofer.de>
To: dakhli malak<dakhli.malak@gmail.com>
Cc: trnsys-users@cae.wisc.edu
Date: Thu, 10 May 2012 09:01:44 +0200
Subject: Re: [TRNSYS-users] solar cooling (H2O/LIBR single effect
absorption machine)
Dear Dakhli,
type107 is a performance map type, i.e. you have to supply a table with
(steady state) operatingg conditions from which the type takes its current
performance (including interpolation).
When you use a calling function like calling EES, you have your chiller
modelled in a different environment (here the Engineering Equation Solver).
There you can have for example an advanced physical model, which might be
hard or impossible to program in sequential fortran code as used for TRNSYS.
Best regards,
Jochen
Am 09.05.2012 10:32, schrieb dakhli malak:
Hi everybody,
i read some articles and i found that some people are using type107 in the
modelling of the machine
and some others are using the calling function of EES. So, what's the
difference between them ?
cordially,
--
______________________________**___________________
Dipl.-Ing. (FH) Jochen Döll
Division Thermal Systems and Buildings
Fraunhofer-Institut für Solare Energiesysteme ISE
Heidenhofstrasse 2, 79110 Freiburg, Germany
Phone: +49 (761) 4588-5468 Fax: +49 (761) 4588-9000
jochen.doell@ise.fraunhofer.de
www.ise.fraunhofer.de
______________________________**___________________
---------- Forwarded message ----------
From: Santeri Siren<santeri.siren1@gmail.com>
To: "trnsys käyttäjät"<trnsys-users@cae.wisc.edu>
Cc:
Date: Thu, 10 May 2012 16:33:51 +0300
Subject: [TRNSYS-users] External data files for heat pump& absorbtion
chiller
Dear all,
I need to use a water to water ground heat pump (type 668) and absorbtion
chiller in my simulations. It seems to be very difficult to find product
catalogues that include the information required in the external data
files. Could someone with experience please tell me which manufacturers do
provide this kind of information and perhaps send me a link. The only
catalogue data file that I was able to for water to water heat pump was
this one from Carrier:
http://www.docs.hvacpartners.com/idc/groups/public/documents/techlit/50psw-3pd.pdf
Best regards. Santeri Siren
---------- Forwarded message ----------
From: Alessandro Rinaldi<alexius87@hotmail.it>
To:<trnsys-users@cae.wisc.edu>
Cc:
Date: Thu, 10 May 2012 18:19:20 +0200
Subject: [TRNSYS-users] insertion of a balcony
hi, which type should I use to insert a balcony that shades the wall
below and the window? thanks